Model No.
Input Voltage Requirements
Minimum Power Requirements
Plug Type
High
220V - 240V, 50/60Hz, 3Ph
47.2KVA/48.4KW
J
Capacity  
Fuses Pipe Sizes
20’’OD – 65’’ OD pipe (500mm – 1600mm)
Weight  
Machine:
14,000 lbs (6350Kg)
Facer:
775 lbs (351.5Kg)
20-48” Heater :
600 lbs (272.2Kg)
48-65” Heater:
700 lbs. (317Kg)
Hydraulics  
System Pressure:
1500 PSI (103.42 BAR) Max.
Hydraulic Reservoir Capacity:
24 Gallons (90.85 Liters)
Motor :
10 HP, 3 Phase, 240V
 
Power  
20-48” Heater Power :
35,000 Watt
48-65” Heater Power :
38,437 Watt
Facer Power :
Hydraulic
Chassis  
Frame:
Welded steel tube construction
Front Axle :
Articulating
Brake :
Mechanical
Mobility  
Tires:
12 - 16.5LTF, F-12
Transportation:
Pulled via towing ring
Lifting :
Lift points & lifting assembly
Warranty  
Term:
3 Years

Features
Dual hydraulic pipe lifts
DataLogger compatible
Patented Centerline guidance for equal distribution of force around the joint
Serrated jaw & inserts to keep pipe from slipping during fusion
Hydraulic facer for facing the heaviest wall pipe with ease
Advance Blade Design for smooth face and long life
Rugged outriggers for added stability
Hydraulic clamping
Hydraulic pivoting heater & facer
Original industry standard for hydraulic control systems
ISO compliant industrial teflon coated plates

 

 

 
 